For stable data reception from the sensor, it is recommended to configure the sensor to output data at an interval of every 10 seconds or more frequently. If using a setting with less frequent data output intervals, the device may periodically "lose" information from the sensor in some situations.
Sensor identification is performed by Sensor Name or MAC address.
If both fields are specified, priority is given to Sensor Name.
Command examples are given for configuration by MAC address.
If you need to configure by Sensor Name, then in the command examples you need to change:
(7,FF:FF:FF:FF:FF:FF,!)to(7,!,TH_000000)Replace in the command:
FF:FF:FF:FF:FF:FFwith the actual MAC address
TH_000000with the actual Sensor Name.
Example for Sensor 1:
*!EDITS BLUETOOTH:GLOBAL(1),CHANNEL1(SENS),SENS1(7,FF:FF:FF:FF:FF:FF,!),US1(1),TS1(0,1),PROTOCOL:FLEX(30,&45[1]163[1]167[1]207[1111]223[1]238[11]),USRPRM1(is1,sl1,ub1,in1),USRPRM2(pr1),USRPRM4(st1,ls1)
Example for Sensor 2:
*!EDITS BLUETOOTH:GLOBAL(1),CHANNEL1(SENS),SENS2(7,FF:FF:FF:FF:FF:FF,!),US2(1),TS2(0,2),PROTOCOL:FLEX(30,&46[1]164[1]168[1]211[1111]224[1]240[11]),USRPRM1(,,,,is2,sl2,ub2,in2),USRPRM2(,pr2),USRPRM4(,,st2,ls2)