This article describes the available methods for changing the monitoring server on NAVTELECOM devices. The methods are listed in descending order of convenience and speed.
Changing servers for legacy device models (S-2551, S-2333, S-2117)
| START | S-20xx, S-40xx |
| SMART | S-24xx, S-45xx |
| SIGNAL | S-26xx, S-46xx, S-47xx |
An Internet command can be sent directly from the server the device is currently connected to, if the following conditions are met:
Short format description:
*!EDITS TRANS:SRV1(PROTOCOL,,,IP,PORT)
IP |
IP address or DNS name of the monitoring server | |
PORT |
Monitoring server port | |
PROTOCOL |
Data exchange protocol with the server. When switching a device to another monitoring server, specifying the protocol is optional. However, the port often depends on the selected protocol. Check the required port with the monitoring server support, providing the device model and data exchange protocol. |
|
FLEX |
FLEX protocol | |
F6 |
F6 protocol (legacy devices S-2551) | |
F5.2 |
F5.2 protocol (devices S-2117) | |
EGTS |
EGTS protocol (identification by "Object ID") | |
EGTSAUTH |
EGTS protocol (identification by IMEI) | |
In the examples below, the server address and port are specified assuming the device will operate using the
FLEXprotocol.
If you use another data exchange protocol, contact the monitoring server support team to obtain the correctIPandPORTparameters.
| Server | Command |
|---|---|
| Fort Monitor | *!EDITS TRANS:SRV1(FLEX,,,dev.fort-monitor.ru,65511) |
| Gelios | *!EDITS TRANS:SRV1(FLEX,,,hw.geliospro.ru,20140) |
| Axenta | *!EDITS TRANS:SRV1(FLEX,,,hw.axenta.cloud,21889) |
| Pilot | *!EDITS TRANS:SRV1(FLEX,,,smart.pilot-gps.com,20052) |
| Waliot | *!EDITS TRANS:SRV1(FLEX,,,device.waliot.com,30003) |
Open object properties:

Create a new command:

Select a custom command and enter the command string as parameters:

Send the command to the object:

An SMS command can be sent to any device if its SIM card number is known and the following conditions are met:
Short format description:
*!EDITS TRANS:SRV1(PROTOCOL,,,IP,PORT)
PASSWORD *!EDITS TRANS:SRV1(PROTOCOL,,,IP,PORT)
PASSWORD |
Password that can be set by the user during device configuration (by default, no SMS control password is set) | |
IP |
IP address or DNS name of the monitoring server | |
PORT |
Monitoring server port | |
PROTOCOL |
Data exchange protocol with the server. When switching a device to another monitoring server, specifying the protocol is optional. However, the port often depends on the selected protocol. Check the required port with the monitoring server support, providing the device model and data exchange protocol. |
|
FLEX |
FLEX protocol | |
F6 |
F6 protocol (legacy devices S-2551) | |
F5.2 |
F5.2 protocol (devices S-2117) | |
EGTS |
EGTS protocol (identification by "Object ID") | |
EGTSAUTH |
EGTS protocol (identification by IMEI) | |
If a password is set in the device configuration for SMS control, you must add the password and a space before
*!.
Detailed example is available in the "Command format" section.
In the examples below, the server address and port are specified assuming the device will operate using the
FLEXprotocol.
If you use another data exchange protocol, contact the monitoring server support team to obtain the correctIPandPORTparameters.
| Server | Command |
|---|---|
| Fort Monitor | *!EDITS TRANS:SRV1(FLEX,,,dev.fort-monitor.ru,65511) |
| Gelios | *!EDITS TRANS:SRV1(FLEX,,,hw.geliospro.ru,20140) |
| Axenta | *!EDITS TRANS:SRV1(FLEX,,,hw.axenta.cloud,21889) |
| Pilot | *!EDITS TRANS:SRV1(FLEX,,,smart.pilot-gps.com,20052) |
| Waliot | *!EDITS TRANS:SRV1(FLEX,,,device.waliot.com,30003) |
A command can be sent via the DRC service if the following conditions are met:
- Registration only needs to be completed once to obtain an Organization ID (after that, you can create multiple user accounts for different employees).
- The remaining steps are described in the "Sending via DRC" section.
Short format description:
*!EDITS TRANS:SRV1(PROTOCOL,,,IP,PORT)
IP |
IP address or DNS name of the monitoring server | |
PORT |
Monitoring server port | |
PROTOCOL |
Data exchange protocol with the server. When switching a device to another monitoring server, specifying the protocol is optional. However, the port often depends on the selected protocol. Check the required port with the monitoring server support, providing the device model and data exchange protocol. |
|
FLEX |
FLEX protocol | |
F6 |
F6 protocol (legacy devices S-2551) | |
F5.2 |
F5.2 protocol (devices S-2117) | |
EGTS |
EGTS protocol (identification by "Object ID") | |
EGTSAUTH |
EGTS protocol (identification by IMEI) | |
In the examples below, the server address and port are specified assuming the device will operate using the
FLEXprotocol.
If you use another data exchange protocol, contact the monitoring server support team to obtain the correctIPandPORTparameters.
| Server | Command |
|---|---|
| Fort Monitor | *!EDITS TRANS:SRV1(FLEX,,,dev.fort-monitor.ru,65511) |
| Gelios | *!EDITS TRANS:SRV1(FLEX,,,hw.geliospro.ru,20140) |
| Axenta | *!EDITS TRANS:SRV1(FLEX,,,hw.axenta.cloud,21889) |
| Pilot | *!EDITS TRANS:SRV1(FLEX,,,smart.pilot-gps.com,20052) |
| Waliot | *!EDITS TRANS:SRV1(FLEX,,,device.waliot.com,30003) |
If objects are already created in the system, go directly to step 4
Add one or more objects

When creating an object, only two parameters are required:
IMEI – always required;Password – required if it is set in the device (if a password exists in the device but is not specified in the DRC object, device control will not be possible)
Select objects (1) and (2), then assign a task (3)

Animation with an example of assigning tasks to multiple objects

Using the configurator, settings can also be changed remotely.
The process is described in detail in the "Editing in configurator" section.
Connect to the device remotely:
Read the current configuration

Edit the server

Do not forget to save the updated configuration to the device

The main method for editing settings is connecting to the device via USB using the configurator.
The process is described in detail in the "Editing in configurator" section.
Connect to the device via USB
In rare cases, there may be issues detecting the device via USB. If this happens, refer to the following article:
Read the current configuration

Edit the server

Do not forget to save the updated configuration to the device